At Energy Exchanger, inspectors with certifications to a minimum of ASNT-TCIA level II in PT, MT and RT film interpretation, report directly to the president. EEC is certified to fabricate to API-660 heat exchanger standards, ASME Section VIII, Division I Pressure Vessels, "U" #12,370, and Section I Power Boilers, "S" #12,371 as well as repairs and alterations  "R" #2,888 and to all standards of the Tubular Exchanger Manufacturers Association (TEMA).

Quality is a state of mind shared by all. This quality is guided by and constantly improved by the Total Quality Management (TQM) process, which Energy has been using and developing for a number years.Total Quality Management is the governing process for quality improvement throughout every department of Energy Exchanger Company.

Level of training of inspectors - Level III and Level II
NDT Equipment
  1. Radiographic - subcontract
  2. Gamma Ray - subcontract
  3. Magnetic Particle - Own ESC-270 1000 AMP (2), Magnaflux Y6 - AC Yoke
  4. Ultrasonic - Own KB USMT-2
  5. Penetrant - Own Aerosol
  6. Others - Telebrineller Tester, Gow-Mac Leak Detector, Severn Ferrite Gauge, Fischer Ferrite Scope

tubeweldpt.jpg (67213 bytes) tubewldpt.jpg (133264 bytes)

Penetrant testing of Titanium tube-to-tubesheet welds